University of Illinois at Urbana-Champaign
Department of Mechanical and Industrial Engineering
IE411 Optimization of Large-Scale Linear Systems
Fall 2018
Coding project: A Revised Simplex Method Code (Due December 18)
In this project, you are asked to form groups with no more than three students in a group to
implement your own revised simplex method code in Matlab.
The input to your code is the following linear program:
min ≥ 0,
where is amatrix,is a column vector in is a row vector in .
Step One
The first step in the project is to implement a Matlab function called simplex_step for executing
a single step of the revised simplex method. We will keep track of the current basic feasible
vector with three variables: iB, iN, and xB. The vector iB will hold the indices of the current set
of basic variables, iN will hold the indices of the current set of nonbasic variables, and xB will
hold the values of the basic variables.
The function simplex_step should be placed in a file simplex_step.m and it should have the
calling sequence:
function [istatus,iB,iN,xB, Binv] = simplex_step(A,b,c,iB,iN,xB,Binv,irule)
%
% Take a single simplex method step for the linear program
%
% min cx
% s.t. Ax=b
% x>=0,
%
% where A is an (m,n) matrix.
%
% That is, given a basic feasible vector described by the variables iB,iN,xB return the values
% of iB,iN, and xB corresponding to the adjacent basic feasible vector arrived at via a
% simplex method step.
%
University of Illinois at Urbana-Champaign
Department of Mechanical and Industrial Engineering
IE411 Optimization of Large-Scale Linear Systems
Fall 2018
% Input Parameters:
%
% A - (m,n) constraint matrix
% b - (m,1) POSITIVE vector appearing in the constraint equation above
% c - (1,n) vector giving the coefficients of the objective function
%
% iB - (1,m) integer vector specifying the indices of the basic
% variables at the beginning of the simplex step
% iN - (1,n-m) integer vector specifying the indices of the nonbasic
% variables at the beginning of the simplex step
% xB - (m,1) vector specifying the values of the basic
% variables at the beginning of the simplex step
% Binv – (m,m) inverse matrix of the basis B
%
% irule - integer parameter speciying which pivot rule to use:
% irule = 0 indicates that the smallest coefficient rule should be
% used
% irule = 1 indicates that Bland’s rule should be used
%
% Output Parameters:
%
% istatus - integer parameter reporting on the progress or lake thereof
% made by this function
% istatus = 0 indicates normal nondegenerate simplex method step
% completed
% istatus = 16 indicates the program is unbounded
% istatus = -1 indicates an optimal feasible vector has been
% found
%
% iB - integer vector specifying the m indices of the basic variables
% after the simplex step
% iN - integer vector specifying the n-m indices of the nonbasic
% variables after the simplex step
% xB - vector of length m specifying the values of the basic
% variables after the simplex step
University of Illinois at Urbana-Champaign
Department of Mechanical and Industrial Engineering
IE411 Optimization of Large-Scale Linear Systems
Fall 2018
%
Make sure that your calling sequence for the function is exactly correct, including ordering of the
input and output parameters, dimensions and choice of integers return parameters.
It is quite easy to verify that your function is working correctly. Please make sure that it performs
the correct operations and reports optimal functions and unboundedness correctly.
Step Two
The second step in the project is to implement a Matlab function for performing initialization as
described in the two-phase method. The function should be called simplex_init and it should be
placed in the file simplex_init.m. The calling sequence for this function is:
function [istatus,iB,iN,xB] = simplex_init(A,b,c)
%
% Attempt to find a basic feasible vector for the linear program
%
% min cx
% s.t. Ax=b
% x>=0,
%
% where A is a (m,n) matrix.
%
% Input Parameters:
%
% A - (m,n) constraint matrix
% b - (m,1) vector appearing in the constraint equation above
% c - (1,n) vector giving the coefficients of the objective function
%
% Output Parameters:
%
% istatus - integer parameter reporting the result of the initialization procedure
% istatus = 0 indicates a basic feasible vector was found
% istatus = 4 indicates that the initialization procedure failed
% istatus = 16 indicates that the problem is infeasible
%
University of Illinois at Urbana-Champaign
Department of Mechanical and Industrial Engineering
IE411 Optimization of Large-Scale Linear Systems
Fall 2018
% iB - integer vector of length m specifying the indices of the basic variables
% iN - integer vector of length n-m specying the indices of the nonbasic variables
% xB - vector of length m specifying the values of the basic variables
%
Again, please make sure that your function conforms exactly to the calling sequence given
above.
Step Three
The final step in the project is the implementation of a Matlab function simplex_method which
used the preceding two functions in order to compute a solution to a linear program.
The calling sequence for the function simplex_method, which should reside in the file
simplex_method.m, is as follows:
function [istatus,X,eta,iB,iN,xB] = simplex_method(A,b,c,irule)
%
% Find a basic optimal solution for the linear program
%
% min cx
% s.t. Ax=b
% x>=0,
%
% where A is an (m,n) matrix.
%
% Input Parameters:
%
% A - (m,n) constraint matrix
% b - (m,1) a vector appearing in the constraint equation above
% c - (1,n) vector giving the coefficients of the objective function
%
% irule - integer parameter speciying which pivot rule to use:
% irule = 0 indicates that the smallest coefficient rule should be used
% irule = 1 indicates that Bland’s rule should be used
%
University of Illinois at Urbana-Champaign
Department of Mechanical and Industrial Engineering
IE411 Optimization of Large-Scale Linear Systems
Fall 2018
% Output Parameters:
%
% istatus - integer parameter reporting the results obtained by this function
% istatus = 0 indicates normal completion (i.e., a solution has been found and reported)
% istatus = 4 indicates the program is infeasible
% istatus = 16 indicates the program is feasible but our initialization procedure has failed
% istatus = 32 indicates that the program is unbounded
%
% X - vector of length n specifying the solution
% eta - the minimum value of the objective function
% iB - integer vector specifying the m indices of the basic variables after the simplex step
% iN - integer vector specifying the n-m indices of the nonbasic variables after the simplex step
% xB - vector of length m specifying the values of the basic variables after the simplex step
%
Grading
We will generate linear program instances to test whether your code returns the correct solutions.
You will receive a full mark if the test is passed. To facilitate the development of your code,
some test files are provided, which should be self-explanatory.
Extra credit: Alternative implementations
In the above implementation, the inverse of the basis is derived by carrying out the pivot. For
sparse problems (problems with a lot of zero elements in A), an alternative implementation is to
store the inverse of the basis as the product of elementary matrices. This leads to fewer storage
and computational burden, and it provides greater numerical stability by reducing accumulated
round-off errors. You will get extra credit if you can also implement this approach and compare
it with the tableau pivoting implementation. Even better if you can carry out the LU factorization
approach. For information of the alternative implementations, please read Bazaraa, Jarvis and
Sherali, Linear Programming and Network Flows (fourth edition), Chapter 5. (You can now
download the e-copy of the book from the library.)
Submission: Please complete the following report and submit it with your code in a
zip file by email to Xin Chen xinchen@illinois.edu and cc the TA Shuanglong Wang
swang157@illinois.edu(one submission for each group)
University of Illinois at Urbana-Champaign
Department of Mechanical and Industrial Engineering
IE411 Optimization of Large-Scale Linear Systems
Fall 2018
In the case the simplex_step input is not consistent with the test code which does not
have BInv, you can choose one of the two options:
1. Remove BInv from the input of simplex_step. This of course means you cannot pass
the information to the next pivot unless you define BInv as a global variable.
2. Keep BInv as an input of simplex_step. You will then change the test code to
accommodate that.
Another thing I would like to mention is the failure of the initialization procedure, which
means that the first phase ends up with an artificial variable still in the basis but taking
value zero when we stop the first phase at an optimal solution.
Team members:
1. Did your code pass all the test cases?
2. Does your code pass the inverse of the basis to the next pivot in your
implementation or not?
3. Did your implement the alternative approach of storing the inverse of the
basis as the product of elementary matrices?
4. Did you implement the LU factorization approach?